Member State report / Art8-2024 / 2024 / D11 / Spain / Mediterranean: Western Mediterranean Sea

Report type Member State report to Commission
MSFD Article Art8
Report due 2024-10-15
GES Descriptor D11 Energy, incl. underwater noise
Member State Spain
Region/subregion Mediterranean: Western Mediterranean Sea
Report date 2026-03-24 07:53:11

Demarcación marina del Estrecho y Alborán (MWE-ES-SD-ESAL)

Regional assessment area
Component MRUs
GES component
D11
D11
D11
D11
D11
Feature
Impulsive sound in water
Impulsive sound in water
Continuous low frequency sound
Continuous low frequency sound
Continuous low frequency sound
Element
Impulsive sound in water
Continuous sound (1/3 octave frequency band centred on 125 Hz)
Continuous sound (1/3 octave frequency band centred on 63 Hz)
Element extent
Trend element
Unknown
Unknown
Unknown
Element 2
Element source
National
National
National
Criterion
D11C1
D11C1
D11C2
D11C2
D11C2
Parameter
Other
LEV-N (125 Hz)
LEV-N (63 Hz)
Threshold value upper
115.0
115.0
Threshold value lower
Threshold value operator
<=
<=
Threshold qualitative
Threshold value source
National
National
Value achieved upper
118.0
124.0
Value achieved lower
Value unit
Other
Other
Proportion threshold value
80.0
80.0
Proportion value achieved
69.0
22.0
Proportion threshold value unit
% area of MRU achieving threshold value
% area of MRU achieving threshold value
% area of MRU achieving threshold value
Trend parameter
Unknown
Unknown
Unknown
Parameter achieved
Unknown
Unknown
Unknown
Description parameter
Sound Pressure Level
Sound Pressure Level
Related indicator
  • RS-IMP
  • RS-AMB
  • RS-AMB
Criteria status
Unknown
Unknown
Unknown
Unknown
Unknown
Description criteria
Ruido impulsivo
Ruido impulsivo
Ruido continuo
Ruido continuo
Ruido continuo
Element status
Unknown
Unknown
Unknown
Description element
Source assessment feature
  • National
  • National
  • National
  • National
  • National
Reporting method feature
Type D
Type D
Type D
Type D
Type D
Trend feature
Unknown
Unknown
Unknown
Unknown
Unknown
Integration rule type parameter
THRES
THRES
THRES
THRES
THRES
Integration rule description parameter
Para la evaluación a corto plazo considera un umbral <= 20 % de área expuesta, como máxima proporción de la unidad de reporte marino que diariamente puede ser perturbada debido a valores superiores al LOBE considerado. Para la evaluación a largo plazo el umbral es <= 10% de área expuesta a valores superiores al LOBE, siendo el área expuesta calculada como promedio anual en base diaria.
Para la evaluación a corto plazo considera un umbral <= 20 % de área expuesta, como máxima proporción de la unidad de reporte marino que diariamente puede ser perturbada debido a valores superiores al LOBE considerado. Para la evaluación a largo plazo el umbral es <= 10% de área expuesta a valores superiores al LOBE, siendo el área expuesta calculada como promedio anual en base diaria.
El porcentaje de área fijado por mensualidad que no debe ser superado en relación a los distintos valores estudiados es <= al 20% del área evaluada.
El porcentaje de área fijado por mensualidad que no debe ser superado en relación a los distintos valores estudiados es <= al 20% del área evaluada.
El porcentaje de área fijado por mensualidad que no debe ser superado en relación a los distintos valores estudiados es <= al 20% del área evaluada.
Integration rule type criteria
Not relevant
Not relevant
Not relevant
Not relevant
Not relevant
Integration rule description criteria
GES extent threshold
GES extent achieved
GES extent unit
Proportion of area in good status
Proportion of area in good status
Proportion of area in good status
Proportion of area in good status
Proportion of area in good status
GES achieved
Unknown
Unknown
Unknown
Unknown
Unknown
Description overall status
Dado que el ejercicio descriptivo del ruido impulsivo se ha llevado a cabo sin disponer de la información de registro necesaria para poder llevar a cabo una evaluación precisa, el estado del criterio D11C1 no puede ser determinado a partir de los estudios presentados y, por lo tando, la evaluación es no concluyente. De la misma manera, no es posible identificar ninguna tendencia de cambio de estado.
Dado que el ejercicio descriptivo del ruido impulsivo se ha llevado a cabo sin disponer de la información de registro necesaria para poder llevar a cabo una evaluación precisa, el estado del criterio D11C1 no puede ser determinado a partir de los estudios presentados y, por lo tando, la evaluación es no concluyente. De la misma manera, no es posible identificar ninguna tendencia de cambio de estado.
Los resultados obtenidos para el valor de SPL utilizado como valor umbral sobre el nivel de presión sonora (115 dB re 1 µPa), supera el umbral máximo del 20% de área para la banda de 1/3 de octava de 63Hz en todas las anualidades evaluadas. En el caso de la banda de 1/3 de ovtava a 125Hz, el área afectada se encuentra por debajo del valor umbral de nivel durante los primeros siete meses de 2020 y en dos meses aislados de 2022, el resto de mensualidades se encuentran superan el valor umbral establecido. Debido a la falta de conocimiento acerca de valores específicos mediante los cuales parametrizar el LOBE en relación con las especies indicadoras presentes en el área, la figura de evaluación no concluyente se escoge como más adecuada.
Los resultados obtenidos para el valor de SPL utilizado como valor umbral sobre el nivel de presión sonora (115 dB re 1 µPa), supera el umbral máximo del 20% de área para la banda de 1/3 de octava de 63Hz en todas las anualidades evaluadas. En el caso de la banda de 1/3 de ovtava a 125Hz, el área afectada se encuentra por debajo del valor umbral de nivel durante los primeros siete meses de 2020 y en dos meses aislados de 2022, el resto de mensualidades se encuentran superan el valor umbral establecido. Debido a la falta de conocimiento acerca de valores específicos mediante los cuales parametrizar el LOBE en relación con las especies indicadoras presentes en el área, la figura de evaluación no concluyente se escoge como más adecuada.
Los resultados obtenidos para el valor de SPL utilizado como valor umbral sobre el nivel de presión sonora (115 dB re 1 µPa), supera el umbral máximo del 20% de área para la banda de 1/3 de octava de 63Hz en todas las anualidades evaluadas. En el caso de la banda de 1/3 de ovtava a 125Hz, el área afectada se encuentra por debajo del valor umbral de nivel durante los primeros siete meses de 2020 y en dos meses aislados de 2022, el resto de mensualidades se encuentran superan el valor umbral establecido. Debido a la falta de conocimiento acerca de valores específicos mediante los cuales parametrizar el LOBE en relación con las especies indicadoras presentes en el área, la figura de evaluación no concluyente se escoge como más adecuada.
Assessments period
2022-2022
2022-2022
2020-2022
2020-2022
2020-2022
Related pressures
  • Input of anthropogenic sound (impulsive, continuous)
  • Input of anthropogenic sound (impulsive, continuous)
  • Input of anthropogenic sound (impulsive, continuous)
  • Input of anthropogenic sound (impulsive, continuous)
  • Input of anthropogenic sound (impulsive, continuous)
Related targets
  • B.18
  • B.22
  • B.23
  • C.11
  • C.14
  • C.15
  • C.16
  • C.17
  • C.18
  • C.19
  • B.18
  • B.22
  • B.23
  • C.11
  • C.14
  • C.15
  • C.16
  • C.17
  • C.18
  • C.19
  • B.17
  • B.22
  • B.23
  • C.11
  • C.14
  • C.15
  • C.16
  • C.17
  • C.18
  • C.19
  • B.17
  • B.22
  • B.23
  • C.11
  • C.14
  • C.15
  • C.16
  • C.17
  • C.18
  • C.19
  • B.17
  • B.22
  • B.23
  • C.11
  • C.14
  • C.15
  • C.16
  • C.17
  • C.18
  • C.19
Test TV
NA
NA
NA
No
No
Test results
Correct
False
False
False
False

Demarcación marina levantino-balear (MWE-ES-SD-LEV)

Regional assessment area
Component MRUs
GES component
D11
D11
D11
D11
D11
Feature
Impulsive sound in water
Impulsive sound in water
Continuous low frequency sound
Continuous low frequency sound
Continuous low frequency sound
Element
Impulsive sound in water
Continuous sound (1/3 octave frequency band centred on 125 Hz)
Continuous sound (1/3 octave frequency band centred on 63 Hz)
Element extent
Trend element
Unknown
Unknown
Unknown
Element 2
Element source
National
National
National
Criterion
D11C1
D11C1
D11C2
D11C2
D11C2
Parameter
Other
LEV-N (125 Hz)
LEV-N (63 Hz)
Threshold value upper
115.0
115.0
Threshold value lower
Threshold value operator
<=
<=
Threshold qualitative
Threshold value source
National
National
Value achieved upper
116.0
122.0
Value achieved lower
Value unit
Other
Other
Proportion threshold value
80.0
80.0
Proportion value achieved
99.0
91.0
Proportion threshold value unit
% area of MRU achieving threshold value
% area of MRU achieving threshold value
% area of MRU achieving threshold value
Trend parameter
Unknown
Unknown
Unknown
Parameter achieved
Unknown
Unknown
Unknown
Description parameter
Sound Pressure Level
Sound Pressure Level
Related indicator
  • RS-IMP
  • RS-AMB
  • RS-AMB
Criteria status
Unknown
Unknown
Unknown
Unknown
Unknown
Description criteria
Ruido impulsivo
Ruido impulsivo
Ruido continuo
Ruido continuo
Ruido continuo
Element status
Unknown
Unknown
Unknown
Description element
Source assessment feature
  • National
  • National
  • National
  • National
  • National
Reporting method feature
Type D
Type D
Type D
Type D
Type D
Trend feature
Unknown
Unknown
Unknown
Unknown
Unknown
Integration rule type parameter
THRES
THRES
THRES
THRES
THRES
Integration rule description parameter
Para la evaluación a corto plazo considera un umbral <= 20 % de área expuesta, como máxima proporción de la unidad de reporte marino que diariamente puede ser perturbada debido a valores superiores al LOBE considerado. Para la evaluación a largo plazo el umbral es <= 10% de área expuesta a valores superiores al LOBE, siendo el área expuesta calculada como promedio anual en base diaria.
Para la evaluación a corto plazo considera un umbral <= 20 % de área expuesta, como máxima proporción de la unidad de reporte marino que diariamente puede ser perturbada debido a valores superiores al LOBE considerado. Para la evaluación a largo plazo el umbral es <= 10% de área expuesta a valores superiores al LOBE, siendo el área expuesta calculada como promedio anual en base diaria.
El porcentaje de área fijado por mensualidad que no debe ser superado en relación a los distintos valores estudiados es <= al 20% del área evaluada.
El porcentaje de área fijado por mensualidad que no debe ser superado en relación a los distintos valores estudiados es <= al 20% del área evaluada.
El porcentaje de área fijado por mensualidad que no debe ser superado en relación a los distintos valores estudiados es <= al 20% del área evaluada.
Integration rule type criteria
Not relevant
Not relevant
Not relevant
Not relevant
Not relevant
Integration rule description criteria
GES extent threshold
GES extent achieved
GES extent unit
Proportion of area in good status
Proportion of area in good status
Proportion of area in good status
Proportion of area in good status
Proportion of area in good status
GES achieved
Unknown
Unknown
Unknown
Unknown
Unknown
Description overall status
Dado que el ejercicio descriptivo del ruido impulsivo se ha llevado a cabo sin disponer de la información necesaria para poder llevar a cabo una evaluación precisa, el estado del criterio D11C1 no puede ser determinado a partir de los resultados presentados en este documento, y por lo tanto, la evaluación es no concluyente. De la misma manera, no es posible identificar ninguna tendencia de cambio de estado.
Dado que el ejercicio descriptivo del ruido impulsivo se ha llevado a cabo sin disponer de la información necesaria para poder llevar a cabo una evaluación precisa, el estado del criterio D11C1 no puede ser determinado a partir de los resultados presentados en este documento, y por lo tanto, la evaluación es no concluyente. De la misma manera, no es posible identificar ninguna tendencia de cambio de estado.
En el caso de considerar como valor umbral sobre el nivel de presión sonora de 115dB para ambas bandas de frecuencia evaluadas no se supera en ninguna mensualidad el nivel umbral máximo permitido del 20% de área afectada. Debido a la falta de conocimiento acerca de valores específicos mediante los cuales parametrizar el LOBE en relación con las especies indicadoras presentes en el área, la figura de evaluación no concluyente se escoge como más adecuada.
En el caso de considerar como valor umbral sobre el nivel de presión sonora de 115dB para ambas bandas de frecuencia evaluadas no se supera en ninguna mensualidad el nivel umbral máximo permitido del 20% de área afectada. Debido a la falta de conocimiento acerca de valores específicos mediante los cuales parametrizar el LOBE en relación con las especies indicadoras presentes en el área, la figura de evaluación no concluyente se escoge como más adecuada.
En el caso de considerar como valor umbral sobre el nivel de presión sonora de 115dB para ambas bandas de frecuencia evaluadas no se supera en ninguna mensualidad el nivel umbral máximo permitido del 20% de área afectada. Debido a la falta de conocimiento acerca de valores específicos mediante los cuales parametrizar el LOBE en relación con las especies indicadoras presentes en el área, la figura de evaluación no concluyente se escoge como más adecuada.
Assessments period
2021-2021
2021-2021
2020-2022
2020-2022
2020-2022
Related pressures
  • Input of anthropogenic sound (impulsive, continuous)
  • Input of anthropogenic sound (impulsive, continuous)
  • Input of anthropogenic sound (impulsive, continuous)
  • Input of anthropogenic sound (impulsive, continuous)
  • Input of anthropogenic sound (impulsive, continuous)
Related targets
  • B.18
  • B.22
  • B.23
  • C.11
  • C.14
  • C.15
  • C.16
  • C.17
  • C.18
  • C.19
  • B.18
  • B.22
  • B.23
  • C.11
  • C.14
  • C.15
  • C.16
  • C.17
  • C.18
  • C.19
  • B.17
  • B.22
  • B.23
  • C.11
  • C.14
  • C.15
  • C.16
  • C.17
  • C.18
  • C.19
  • B.17
  • B.22
  • B.23
  • C.11
  • C.14
  • C.15
  • C.16
  • C.17
  • C.18
  • C.19
  • B.17
  • B.22
  • B.23
  • C.11
  • C.14
  • C.15
  • C.16
  • C.17
  • C.18
  • C.19
Test TV
NA
NA
NA
No
No
Test results
Correct
False
False
False